Pointek CLS200/300 (standard)
Note: Pointek CLS200/300 is to be used only in the manner outlined in this manual, otherwise
protection provided by the equipment may be impaired.
This product is intended for use in industrial areas. Operation of this equipment in a
residential area may cause interference to several frequency based communications.
Pointek CLS200/300 is a versatile capacitance switch
with a high level of chemical resistance; ideal for level
detection of interfaces, solids, liquids, slurries, and
foam, and for simple pump control.
Approvals (verify against device
nameplate)
• CE, CSA
, FM, ATEX
C/US
• Vlarem II, WHG
• Lloyd's Register of Shipping, categories ENV1,
ENV2, and ENV5
Note: The use of approved watertight conduit
hubs/glands is required for Type 4 / NEMA 4,
Type 6 / NEMA 6, IP68 (outdoor applications).
Process connections
Compact (std.) configuration
Sanitary configuration
Cable and slide coupling
configuration
Ambient Conditions
• general applications
• in potential explosive
atmospheres
Process Conditions
Please see full Operating Instructions for Process Pressure/Temperature De-
Note:
rating Curves.
• relative dielectric constant (ε
• CLS200 temperature
- without thermal isolator–40 to +85 °C (–40 to +185 °F)
- with thermal isolator
1.
At process connection.
7ML19985QY81
Pointek CLS200/300 (Standard) – QUICK START MANUAL
R ¾", 1", 1 1/4", 1 ½" BSPT; ¾", 1", 1 1/4", 1 ½" NPT; G ¾", 1",
1 ½" BSPP
1", 1 ½", 2", 2 ½"and 3" tri-clamp
R ¾", 1", 1 1/4", 1 ½" BSPT; ¾", 1", 1 1/4", 1 ½" NPT (Taper);
G ¾", 1", 1 ½" BSPP
–40 to +85 °C (–40 to +185 °F)
check temperature class shown on device nameplate
)1.5 minimum
r
1
:
–40 to +125 °C (–40 to +257 °F)
standard version
lid without window
device
nameplate
Page EN-3