Quick start-up guide for ACS880 drives with primary control program 11
13.12 AO1 source
13.17 AO1 source min
13.18 AO1 source max
13.19 AO1 out at AI1 src min
13.20 AO1 out at AI1 src max
Parameter 13.12 selects the source for analog output AO1 (by default, motor speed in
rpm).
Parameters 13.17 and 13.18 set low and high source signal values that correspond to the
actual analog output values defined by parameters 13.19 and 13.20.
46.10 Speed scaling
23.11 Ramp set selection
23.12 Acceleration time 1
23.13 Deceleration time 1
23.14 Acceleration time 2
23.15 Deceleration time 2
You can define two different sets of acceleration/deceleration ramps. The source that
switches between the two sets is selected by parameter 23.11.
Each acceleration/deceleration time set in parameters 23.12...23.15 refers to the time it
takes for the drive to accelerate or decelerate between 0 and scaling speed (parameter
46.10).
0
Source signal
13.18
13.19
13.17
Speed
46.10
Acc.
23.12
23.14
AO (mA)
13.20
Dec.
Time
23.13
23.15