22
| Configuration
Icon
Vacuum
cleaner
Cooker Hood
User lock
Configurable
Digital Input
Configurable
Digital Input
Configurable
Digital Input
Pressure
Guard
8.7

Main menu

User settings and advanced settings
8.7.1

Unit Information

A basic read-only information about status of the unit, configured components and inputs/outputs.
Text
Function sets speed of supply air fan to High level and extract air fan to Low
level to increase air pressure within the apartment for better dust collection
through central vacuum cleaner.
Function can be activated via digital input — Central Vacuum Cleaner
Function.
Always active while digital input is activated.
Sets speed of both supply and extract air fans to Maximum level to increase
airflow in the cooker hood.
Function can be activated via digital input — Cooker Hood Function.
Function indicates that the system is locked with a password and cannot be
edited or settings changed in any way. System must be unlocked first to make
changes.
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
High–priority function.
1
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Mid–priority function.
2
Configurable digital input for custom user function. Airflow levels for both fans
are freely configurable.
Low–priority function.
3
Configurable digital input for pressure guard connection. Airflow levels for both
fans are freely configurable.
Description