Herunterladen Inhalt Inhalt Diese Seite drucken

Short Description Of The Kawe Examination Light; General Product Description; Operating The Kawe Examination Light; Switching The Light On/Off - KaWe Masterlight Gebrauchsanweisung

Untersuchungsleuchten led, 18w und 18w, fokus
Vorschau ausblenden Andere Handbücher für Masterlight:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Symbol key:
Caution!
Important assembly instructions,
useful information and user tips
Temperature limit
Separate disposal of electric
and electronic devices
Complies with relevant EU guidelines
Heed the User's Manual
Alternating current
Bulb
Protective earth connection
Protection class II
Fuse
Manufacturer
Series number
SN
Product reference number
REF
Non-ionizing radiation

2. SHORT DESCRIPTION OF THE KaWe EXAMINATION LIGHT

Information about intended use: The KaWe examination lights
were developed to be used by doctors in hospitals or in clinics in order
to illuminate areas of patient's bodies during medical examinations.
Main function: The KaWe examination light serves to provide illu-
mination.

General product description

• This is a KaWe examination light as described in EN 60601-2-41,
which as individual luminaries, are not failsafe.
• The KaWe examination light is intended to aid in treatment and di-
agnosis.
• The KaWe examination light is used in areas used for medical rea-
sons (group 0, 1 and 2 according to DIN VDE 0100-710 and HD
60364-7-710).
• The lights are mounted on a stand.
• The lights are to be serviced every 2 years.
The KaWe examination light is avaiable in the following versions: 18W
(fixed focus) – with electronic brightness control and 18W, Focus –
with focusable light spot and electronic brightness control.
14

3. OPERATING THE KaWe EXAMINATION LIGHT

3.1 Switching the light ON/OFF

The KaWe examination light is turned OFF and ON using button 1 on
the control panel.

3.2 Brightness control

The KaWe examination lights are all equipped with a brightness con-
trol function. The lamp models offer brightness modulation between
50% and 100% allowing the brightness of the light to be selected as
required. By pressing button 2, the brightness can be reduced. But-
ton 3 increases the brightness. The selected intensity is visible on the
display 4.

3.3 Focussing (only 18W, Focus)

The KaWe examination light 18W has a light spot that can be focused,
meaning it can be enlarged or made smaller as the situation requires.
To focus the light spot, turn the handle 5 on the light body (see image).

3.4 Positioning

Use the handle 5/6 or both handlebars 7 to position the light body
as desired.
The outer handlebars are used to position the light before a procedure.
The handle is used to reposition the KaWe examination light during
surgical procedures.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis