WATE R C O NNEC TI O NS
The water connections must be carried out by en expert.
For the water connection, a normal cold-water supply
with at least 0,1 MPa (1 bar) water pressure is required.
f In the event of water pressure over 1 MPa (10 bar)
include an upstream pressure valve.
f Observe the connection plans :
Installation plan
(Water and waste water)
f The supplied feet hoses must be used for the water
connection (¾").
f As spare parts, use only hoses which are suited for water
temperatures up to 70 °C and with a minimum bursting
pressure of 70 bar overpressure. Original spare parts fulfil
these requirements.
f Hot water must not exceed the maximum temperature
of 70 °C.
f Important, the connection points are under full water
pressure; check for water tightness with the tap turned
on fully.
f Do not connect the appliance to the mixer tap of an
un pressurised water heater.
f The dirt screens at the loose end of the feed hose and
in the solenoid valve in the appliance should only be
removed for cleaning purposes.
f To prevent water damage, the stop-cock or inter-
mediate valve must be closed on completion of washing.
Connecting the water valves
f Observe the distribution diagram (see also the adhe-
sive label on the rear of the washing machine).
Connection
Existing
parameters
supply lines
DO3 = 1
 
DO3 = 2
  
DO3 = 3
 
DO3 = 3
= Soft water
= Hard water
= Warm water (max. 70 °C)
34
E NGLISH
Water installation diagram
(Hard, soft and hot water)
305 315
Distribution to the valves (¾")
Connecting the drain hose
f Connect the drain hose directly to the drain tube at
the rear of the machine.
305 142
ST E AM H E AT IN G CON N E C TI O N
The connection for the direct and indirect steam heating
is located on the rear side of the machine at the bottom
(see Installation Plan / Item 16).
A special screw connection limits the steam flow.
The screw connection has been fitted with a drill hole
with a diameter of 2.8 mm in the factory.
Depending on the steam pressure of the supply line, the
drill hole must, however, be drilled out additionally.
The suitable drilling diameter in relationship to the steam
pressure can be found in the corresponding diagram.