Electrical connection

Connection of the appliance to the power supply must
be carried out by a specialised electrician.
Prepare the electrical connection (in the building) flexibly
in accordance with the connection diagram and the
regulations of the regional power supply company.
The protective conductor connection is to be designed
in such a way that the protective wire only breaks in the
case of excessive tensile load after all active (current­
carrying) lines have been isolated.
In rooms in which fault­current protective switches are
required or recommended in order to increase safety,
the release current must be 30 mA.
Use a fault­current protective switch with the
The motor is provided with overload protection.
The main switch can be locked in the «OFF» position
z Fuses are not included in the scope of supply.
Important
On completion of setting up and connection of the
washing machine, all removed housing parts must be
refitted to prevent access to current-carrying or rotating
machinery parts.
34
E
8 kg /10 kg / 12 kg washing machine
400 V 3N ~
Reduced mains power
«OFF»
symbol.
Heating
Motor
Fuse
230V 3 ~
Reduced mains power
«OFF»
Heating
Motor
Fuse
400V 2N ~
Reduced mains power
«ON»
9 kW
Heating
0,8 kW
Motor
16 AT
Fuse
230V 1N ~
9 kW
Locking for electrical heating
0,8 kW
Accessory No. 50 998
25 AT
6 kW
0,8 kW
16 AT