Caution – The chassis is heavy. In the following procedures, two people are
!
required to move the chassis. Two people are also required to align and install the
slide assemblies in the rack.
Caution – For proper ventilation, each Sun Enterprise 250 server in the rack
!
enclosure requires 28 square inches (175 square cm) of unrestricted airflow into the
front of the system, and 23 square inches (143 square cm) of unrestricted exhaust
port at the rear of the system. Maintain a minimum 1.5 inches (3.8 cm) clearance
between the system and any front or rear doors.
1-2
Sun Enterprise 250 Server Rackmounting Guide • February 1999