5. Technical specifications
Model
Art.no.
Rated capacity / current
Chosen capacity / current
Electrical connection
Minimum required cable size
Hot water (l/min)
max.at
t = 28K
max.at
t = 38K
Rated volume
Type
max. pressure primary side
max. temperature primary side
Heating system
@ 15°C:
Required spec. water resistance
spec. electrical conductivity
Required flow rate to switch on
Temperature range
Water connection
Weight (when filled with water)
Type of protection / safety
14
12
10
8
6
4
2
0
0,5
1,0
18kW (26A)
21kW (30A)
3/PE 380..415VAC / 230 VAC
2
4,0mm
9,2
6,8
geschlossen, 1MPa(10bar) Nennüberdruck,
Blankdraht IES  / bare wire system IES 
1,5
2,0
2,5
Differenzdruck bar
FWS 27 Frischwasserstation
367 310
18kW ... 27kW (26A ... 39A)
24kW (35A)
2
4,0mm
6,0mm
10,7
12,3
7,9
9,0
2,8 l
Pressure type 1MPa (10 bar)
3 bar
80°C
>1100cm
< 90mS/m
2,5 l/min
30°C - 60°C
4xIG3/4"
23kg
IP 21
Fig. 1:
Flow rate of the FWS 27 in accord-
ance to the upstream pressure of
the cold water inlet.
3,0
3,5
4,0
20
27kW (39A)
3/PE 400VAC/
230VAC
2
2
6,0mm
13,8
10,2
 