Operating information

• Only use the device when installed in a heating boiler.
• Allow the device to cool down after ignition
– Connection: Blower and heating separate, switch off heating and ventilate with blower.
– Connection: Blower and heating, switch off heating and ventilate with secondary blower.
• The installation should be as horizontal as possible (reduces the smoke gas back-pressure).
• Only suck in clean air (see accessories 107.286 and 107.287).
Connection
Blower and heating separate
Brown (heating phase)

Accessories

Only Leister accessories may be used.
107.286 Air hose
107.287 Hose bracket
150.873 Heating element 120 V~ 1050 W
142.718 Heating element 120 V~ 1550W
150.872 Heating element 230 V~ 550 W
150.871 Heating element 230 V~ 1050 W
142.717 Heating element 230 V~ 1550 W
145.606 Heating element (BR4) 230 V~ 3300 W

Replacing the heating elements

1
5
gray (neutral conductor)
Black (blower phase)
2
6
Blower and heating
Brown (heating phase) gray (neutral conductor)
142.967 Power supply cord (Rubber)
with WAGO Plug 3 × 1 mm² × 3 m
143.131 Power supply cord (Silicone)
with WAGO Plug 3 × 1 mm² × 3 m
142.976 Plug with strain relief, kit (WAGO 770)
cable ø 4.5 – 8 mm
148.429 Plug with strain relief, kit (WAGO 770)
(BR4) cable ø 8 – 11.5 mm
3
7
Brown (blower phase)
4
9