• Ensure accurate shaft alignment. If shaft and
flange are not correctly aligned, strain on the
bearings will result, which will overheat and be
irreparably damaged.

4. Electrical connection

• Switch power off before any plug is inserted or
removed!
• Any wiring must only be carried out without power.
• Provide stranded wires with ferrules.
• Check all lines and connections before switching
on the equipment.
• The encoder's and follower electronic's (e. g.
control unit) operating supply must be switched
on simultaneously.
• Encoders with parallel output: Unconnected signal
lines must be provided with a resistor (e. g.: R =
10 kOhm) and connected to earth.
Interference and distortion
All connections are protected against the effects of
interference. The location should be selected to
ensure that no capacitive or inductive interfe-
rences can affect the encoder or the connection
lines! Suitable wiring layout and choice of cable
can minimise the effects of interference (e. g. in-
terference caused by SMPS, motors, cyclic controls
and contactors).
Necessary measures:
• Only screened cable should be used. Wire cross
section is to be at least 0,14 mm², max. 0,5 mm².
• Wiring to the screen and ground (0 V) must be
secured to a good point.
• The system should be positioned well away from
cables with interference; if necessary a protective
screen or metal housing must be provided. The
running of wiring parallel to the mains supply
should be avoided.
• Contactor coils must be linked with spark sup-
pression.
Power supply
Supply voltage depends on the unit type and is in-
dicated in the delivery documentation and on the
identification plate.
10 ... 30 V d.c. (PP, PN, OP, ON, OE, OC, LD24)
5 V d.c. ± 5% (LD)
8
IG06, IG16, IG07, IG17
General information
The following points should be observed:
• Use for soldering precision copper bit (perfor-
mance 15 ... 50 Watt max.).
• Use only tin solder wire type Pb Sn 60 with colo-
phonium fluxing agent (DIN 8516).
• Cable outer and screening must be able to slide to
allow easy mounting.
• If possible, use only the sreened cables recom-
mended in the list below.
Output circuit
IG06, IG16:
PP, OC
IG07, IG17:
PP, PN
OP, ON (AXX, AX0,
ABX, AXI)
OP, ON, OC, OE (AB0,
ABI)
LD, LD24
4.1 Connection type E1/...
Output circuit PP, OC (IG06, IG16):
Output circuit PP, PN (IG07, IG17):
Output circuit OP, ON (IG07, IG17 version AXX, AX0,
AXI, ABX):
Output circuit OP, ON, OC, OE (IG07, IG17 version
AB0, ABI):
Datum 25.03.2013
Recommended cable
LiYCY 5x0,25 mm²
LiYCY 5x0,5 mm²
LiYCY 7x0,38 mm²
LiYCY 10x0,25 mm²
2-LiYCY 12x0,14 mm²,
twisted in pairs
Color
grey
yellow
white
green
brown
Color
grey
yellow
white
brown
pink
blue
Color
yellow
white
green
pink
blue
Art.Nr. 79650
Outside
diameter
ca. 5,4 mm
ca. 7,2 mm
ca. 6,8 mm
ca. 7,3 mm
ca. 7,8 mm
Designation
GND
channel A
channel B
channel 0/I
+UB
Designation
GND
channel A
channel B; 0
+UB
channel /A
channel /B; I
Designation
channel A
channel B
channel 0
channel /A
channel /B
Änd. Stand 106/13