Installation instructions
Glass ceramic hob Toptronic
With normal mounting frame

Electrical connections

Electrical connections must be established by trained electricians in accordance with the regula
tions of NIN and the local electricity supply companies.
A mains isolating device with 3 mm contact opening should be provided in the house wiring sys
tem. Switches, plug and socket devices, circuit breakers and fusible cut outs which are accessi
ble after installation and which have all poles switching are permissible as isolating devices.
Effective earthing and separately installed neutral and earth conductors (schematic diagram
TN S) ensure safe and fault free operation. Existing installations should always be checked.
Type
Voltage
400 V 2~ 50 Hz
GK45TEC
400 V 3~ 50 Hz
400 V 2~ 50 Hz
GK45TEVC / GK45TERC
400 V 3~ 50 Hz
The appliance is equipped with a mains cable that should be connected to a distribution box by the customer. For pyrometric
reasons the connection cable is not to be exchanged. If an oven is installed under the appliance, we recommend placing the
distribution box behind the base. A cut-out can be made in the rear wall for the cables.
Distribution box
Installation pipe
Clamp
600/550
Installation
The distance from the appliance cut out to flammable walls (left, right and rear) must be at least
50 mm. Parts such as partition walls, reinforcing strips which protrude into the installation
space under the cooking zone must be of non flammable materials.
The distance between the underside of the appliance tray and any kitchen unit parts of flamma
ble material must be at least 20 mm. When installed directly under a drawer and if the tray
should be contactable from below without the aid of tools, the thermal screen set must be used
(see «Accessories»). See J402.70 for the relevant installation instructions.
Information
The worktop must be flat and at least 30 mm thick.
Rated load Fuse protection
16 A
6500 W
10 A
16 A
7800 W
10 A
400 V 2~
L2 gray
black
L1
brown
400 V 3~
PE/
yellow/green
J417.00 6
26.5.08 ITH
14/16
L3 gray
L2 black
L1 brown
PE/
yellow/green