Technical data
Input data
Rated input voltage
Output factor correction
Input frequency
Efficiency at 230 Vw
Input current
Starting current (typical for cold start)
Leakage current
Output data
Charging voltage
Retention voltage
Current
Charging current
Rated power

Protective devices

Output side short circuit
Overvoltage
Battery charger over temperature
Battery over temperature
28
Perfect Charge CA 360
90 – 253 Vw
> 97 % (full load)
47 Hz – 63 Hz
87%
4.5 A at 115 Vw
1.8 A at 230 Vw
27 A at 115 Vw
54 A at 230 Vw
< 1 mA at 240 Vw
Lead starter
Absorbed
batteries:
glass mat
(AGM) bat-
teries
14.4 V
14.7 V
13.8 V
13.6 V
Max. 25 A
0 – 25 A
360 W
Current is reduced to 25% of the maxi-
mum current
16 V
78 °C ± 5 °C (measured internally)
52 °C ± 5°C (with battery sensor)
Mainte-
nance-free
batteries
14.6 V
13.25 V