Some device alarms, specifically their thresholds are configurable:
Alarm Meaning
Description
OverVoltage
Triggers an alarm if the DC input voltage reaches the
OVP
Protection
defined threshold. The DC input will be switched off..
OverCurrent
Triggers an alarm if the DC input current reaches the
OCP
Protection
defined threshold. The DC input will be switched off..
OverPower
Triggers an alarm if the DC input power reaches the
OPP
Protection
defined threshold, The DC input will be switched off..
These device alarms can't be configured and are based on hardware:
Alarm Meaning
Description
AC supply over- or undervoltage. Triggers an alarm if the AC supply is out
PF
Power Fail
of specification or when the device is cut from supply, for example when
switching it off with the power switch. The DC input will be switched off.
OverTem-
Triggers an alarm if the internal temperature exceeds a certain limit.
OT
perature
The DC input will be switched off.
Triggers an alarm if the master of an initialised master-slave system
Master-Slave
loses contact to any slave unit or if a slave has not yet been initialised by
MSP
Protection
the master. The DC input will be switched off. The alarm can be cleared
by either deactivating master-slave mode or reinitialising the MS system.
► How to configure the device alarms
1.
While the DC input is switched off tap the touch area
2.
On the right side tap the arrows to select "2. Protect".
3.
Set the thresholds for the equipment alarm relevant to your application if the default value of 103% resp.
110% is unsuitable.
The set values can also be entered using a numeric pad, which appears when tapping the
numeric pad symbol on this screen.
The user also has the possibility of selecting whether an additional acoustic signal will be sounded if an alarm or
user defined event occurs.
► How to configure the alarm sound (also see "„3.4.3. Configuration via MENU")
1.
While the DC input is switched off tap the touch area
2.
In the menu page, tap "HMI Settings".
3.
In the following menu page, tap "Alarm Sound".
4.
In the settings page tap on the symbol to either enable or disable the alarm sound and confirm with
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
EL 9000 B Series
Range
Indication
Display, analog &
0 V...1.03*U
Nom
digital interface
Display, analog &
0 A....1.1*I
Nom
digital interface
Display, analog &
0 W...1.1*P
Nom
digital interface
Indication
Display, analog &
digital interfaces
Display, analog &
digital interfaces
Display, digital
interfaces
on the main screen.
on the main screen.
www.elektroautomatik.de
ea1974@elektroautomatik.de
.
Page 63