Herunterladen Inhalt Inhalt Diese Seite drucken

Usb Port (Type B, Rear Side); Interface Module Slot; Analog Interface - Elektro-Automatik EL 9080-170 B Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1.9.7

USB port (type B, rear side)

The USB-B port on the rear side of the device is provided for communication with the device
and for firmware updates. The included USB cable can be used to connect the device to a
PC (USB 2.0 or 3.0). The driver is delivered on the included medium (USB stick) and installs
a virtual COM port.
The device can be addressed via this port either using the international standard ModBus
RTU protocol or by SCPI language. The device recognises the used message protocol
automatically. Details about remote control can be found in a programming guide which is
also on the included USB stick or on the web site of Elektro-Automatik.
If remote control is in operation the USB port has no priority over any of the other interfaces,
digital or analog, and can therefore only be used alternatively to these. However, monitoring
is always available.
1.9.8

Interface module slot

This slot on the rear side of the device is only available with standard models, i. e. those
where option 3W isn't installed, and is used to install various interface modules types of the
IF-AB interface series. The following interfaces are available:
Article number Name
35400100
IF-AB-CANO
35400101
IF-AB-RS232
35400103
IF-AB-PBUS
35400104
IF-AB-ETH1P
35400105
IF-AB-PNET1P
35400107
IF-AB-MBUS1P
35400108
IF-AB-ETH2P
35400109
IF-AB-MBUS2P
35400110
IF-AB-PNET2P
35400111
IF-AB-CAN
35400112
IF-AB-ECT
The modules are installed by the user and can be retrofitted without problem. A firmware update of the device may
be necessary in order to recognize and support certain modules.
If remote control is in operation the interface module has no priority over either the USB port or the analog interface
and can, therefore, only be used alternately to these. However, monitoring is always available.
Switch off device before adding or removing modules!
1.9.9

Analog interface

This 15 pole Sub-D socket on the rear side of the device is provided for remote control of
the device via analog or digital signals.
If remote control is in operation this analog interface can only be used alternately to the
digital interface. However, monitoring is always available.
The input voltage range of the set values and the output voltage range of the monitor val-
ues, as well as reference voltage level can be switched in the settings menu of the device
between 0-5 V and 0-10 V, in each case for 0-100%.
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Description
CANopen, 1x Sub-D 9-pole male
RS 232, 1x Sub-D 9-pole male (null modem)
Profibus DP-V1 Slave, 1x Sub-D 9-pole female
Ethernet, 1x RJ45
ProfiNET IO, 1x RJ45
ModBus TCP, 1x RJ45
Ethernet, 2x RJ45
ModBus TCP, 2x RJ45
ProfiNET IO, 2x RJ45
CAN 2.0A & 2.0B, 1x Sub-D 9-pole male
EtherCAT, 1x RJ45
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
EL 9000 B Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
Page 30

Werbung

Kapitel

Inhaltsverzeichnis
loading