Malfunction
Motor runs very slowly.
Motor does not run or
stops immediately.
No speed difference be-
tween level I and level II.
Clipper cuts badly or not
at all.
Motor unit becomes hot.
Instruction Manual / Xpert 2-Speed sheep clipper
Cause
Clipper blades were not
oiled sufficiently.
Motor and/or electronics
defective.
Clipping pressure too
strong.
Smell of burning from
the motor housing. Motor
burned out.
Motor and/or electronics
defective.
Motor turns off due to
overload.
Motor and/or electronics
defective.
Magnet missing.
Clipper blades blunt.
Clipper blades have not
been correctly ground.
Clipping pressure too low. Increase the clipping
Shearing blade is incor-
rectly installed and/or
aligned.
The animal's hair is wet.
Hairs stuck between up-
per and lower blade.
Air filter clogged.
Clipping pressure too
high.
Bearing faulty.
Rectification
Lubricate the clipping
blades.
Notify customer service.
Reduce the clipping
pressure, as described
in chapter 6.2. Have the
blades sharpened.
Notify customer service.
Turn off the device, allow
it to cool down and then
turn it on again. Notify
customer service if the
device is not working
properly.
Notify customer service.
Notify customer service.
pressure, as described in
chapter 6.2.
Correctly install the
shearing blade, as
described in chapter 6.5.
Align the clipping blades
correctly, see Fig. 10.
Only clip dry hair.
Remove the clipping
blades; clean, lubricate
and install them again; set
the clipping pressure.
Clean or replace the air
filter.
Reduce the clipping pres-
sure.
Notify customer service.
17

Werbung

Inhaltsverzeichnis
loading