Caution
The relay outputs on the accessory card can have
a max load of 2 A (230 V) in total.
Connecting sensors
Use cable type LiYY, EKKX or similar.
Sensor, solar panel (BT53)
Connect the sensor (solar panel) to AA5-X2:23-24.
Caution
Sensor cable splicing must fulfil IP54.
Sensor, solar coil (BT54)
Connect the sensor (solar coil) to AA5-X2:21-22.
-X9
9
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
-X8
-X2
7
6
5
-X4
4
1
3
2
2
3
1
4
-X10
5
6
-X1
7
N
8
L
PE
PE
Connection of the circulation pump (GP4)
Connect the circulation pump (GP4) to AA5-X9:2 (230
V), AA5-X9:1 (N) and X1:3 (PE).
-X9
9
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
-X8
-X2
7
6
5
-X4
4
1
3
2
2
3
1
4
-X10
5
6
-X1
7
N
8
L
PE
PE
Connecting solar panel cooling
Connect solar panel cooling (if applicable) to AA5-X9:3
(N) and AA5-X9:4 (230 V).
-X9
9
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
8
-X8
-X2
7
6
5
-X4
4
1
3
2
2
3
1
4
-X10
5
6
-X1
7
N
8
L
PE
PE
12
24
23
22
21
20
19
18
17
16
15
14
Unit box External
4
3
L
2
N
1
PE
AA5-X9
1
2
3
X1
9
8
7
6
5
4
3
2
1
DIP switch
The DIP switch on the accessory card must be set as fol-
lows.
24
23
22
21
20
19
18
17
16
15
14
13
12
-X8
-X2
-X4
1
2
3
4
5
6
7
8

Program settings

Program setting of SOLAR 42 can be performed via the
start guide or directly in the menu system.
Caution
Also see the Installer manual for F1145.
Caution
This accessory may require a program software
update in your F1145.
13
1031 or higher is the minimum software version
for the pump.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
GP4
Menu 5.2 - system settings
Activating/deactivating of accessories.
Select: solar heating
Menu 5.3.4 - solar heating
Settings for solar heating.
Menu 5.6 - forced control
Forced control of the different components in the heat
pump as well as in the different accessories that may be
connected.
EP30-AA5-K1: Activating the circulation pump (GP4).
EP30-AA5-K2: Activating solar panel cooling.
EP30-AA5-K3: Signal to three way valve (QN23).
EP30-AA5-K4: No function.
-X9
9
11
10
9
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
-X10
-X1
N
L
PE
PE

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis