4

Startup

4.1 Interface configuration

4.1.1 RS485/RS422

Jumpers J7 – J8 are used to configure the asynchronous interface as an RS485 or R422 port.
Jumper
J7
J8
Table 4-1: Configuration of the RS485/RS422 port
Any termination resistors needed can be enabled using jumpers J1 through J6.
Jumper
J1
J2
J5
J3
J4
J6
Table 4-2: Termination resistors for RS485/RS422
FEIG ELECTRONIC GmbH
RS485
closed
closed
Closed
Pull-Up on RS4xx - B
Pull-Down on RS4xx - A
Termination resistor
RS4xx - A ⇔ RS4xx - B
Pull-Up on RS422 - Z
Pull-Down on RS422 - Y
Termination resistor
RS422 - Y ⇔ RS422 - Z
Page 51 of 56
Installation
RS422
open
open
Open
without Pull-Up on RS4xx - B
without Pull-Down on RS4xx – A
without Termination resistor
RS485 - A ⇔ RS485 - B
without Pull-Up on RS422 - Z
without Pull-Down on RS422 –
Y
without Termination resistor
RS422 - Y ⇔ RS422 - Z