CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Fitting lamp:
OMNILUX PAR-38 ES 230V/20W E27
GE PAR-38 230V/80W E-27 SP
OMNILUX PAR-38 230V/80W E-27 SP 2000h
GE PAR-38 230V/80W E-27 FL
OMNILUX PAR-38 230V/80W E-27 FL 2000h
Maximum ambient temperature t
Maximum housing temperature t
Minimum distance:
Please note: Every information is subject to change without prior notice. 24.08.2005 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
:
a
:
B
max. 230 V AC, 50-60 Hz ~
max. 85 W
200 x 200 x 250 mm
0.6 kg
No.:
88080505
88081000
88081005
88081100
88081105
45° C
100° C
0.5 m
18/33
41929100_V_1_1.DOC

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis