Herunterladen Inhalt Inhalt Diese Seite drucken

Hydraulic System Requirements; Typical Layout; Performance Charts - Ramsey Winch RPH 42,2 Originalanleitung

Planetary winch
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Refer to the performance charts below to properly match your hydraulic system to the winch performance. The
charts consist of: (1) Line Pull first layer kN (lb) vs. Working Pressure bar (PSI). (2) Line Speed, first layer MPM
(FPM) vs. flow LPM.

HYDRAULIC SYSTEM REQUIREMENTS

1.
Motor spool (open center) control valve
2.
Emergency Stop:
A. If winch is controlled by a direct-operated manual valve, that valve serves as the E-stop.
B. If a remote operated control valve is used, a solenoid-operated hydraulic dump valve, normally open to
tank, and an emergency stop switch (to open the dump valve) is required. The E-stop switch is to be
normally closed and have a red, resettable push button actuator with a yellow background. The E-stop
switch must be easily accessible to the operator.
3.
Relief valve set to 144,7 bar (2100 psi) which is the rated capacity limiter.
4.
Flow rate of 56,7 LPM (15 GPM) maximum. Do not exceed 75,7 LPM (20 GPM) or motor and winch may be damaged.
5.
Hydraulic fluid with a viscosity between 20-43 cSt (100-200 SUS). Maximum operating temperature 85C (180F).
Cleanliness level of ISO 17-14 or better.

TYPICAL LAYOUT

MOTOR
BRAKE
PORT

PERFORMANCE CHARTS

10,7 (35)
9,1 (30)
7,6 (25)
6,1 (20)
4,6 (15)
3,0 (10)
1,5 (5)
0
0
(0)
FLOW LPM (GPM)
DUAL-A & B PORT CONTROL
WITH BRAKE RELEASE SHUTTLE
(MOTOR SPOOL)
*
18,9
37,9
(5)
(10)
BASED ON 408 cc (24.9 cu in) MOTOR
PROVIDED BY USER
LOW PRESSURE LINE
HIGH PRESSURE LINE
19 mm (.75 in) I.D. MINIMUM
12,7 mm (.50 in)
I.D. MINIMUM
3 POSITION
4 WAY VALVE
SYSTEM RELIEF
144,7 BAR (2100 PSI)
(RATED CAPACITY LIMITER)
REQUIRED ONLY IF REMOTE-OPERATED CONTROL VALVE IS USED. SEE 2B
IN HYDRAULIC SYSTEMS REQUIREMENTS. NOT REQUIRED FOR A
DIRECT-OPERATED MANUAL VALVE.
42,2 (9480)
40,0 (9000)
35,6 (8000)
31,1 (7000)
26,7 (6000)
22,2 (5000)
17,8 (4000)
13,3 (3000)
8,9 (2000)
4,4 (1000)
0
56,7
0
(15)
(0)
WORKING PRESSURE bar (PSI) AT 56,7 LPM (15 GPM)
7
*
DUMP VALVE
PUMP
MAX. FLOW &
PRESSURE AT
RATED LOAD:
56,7 LPM (15 GPM)
144,7 bar (2100 PSI)
*
E-STOP SWITCH
34,5
70,0
103,4
137,9
(500)
(1000)
(1500)
(2000)
172,4
(2500)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis