Error Messages

When you turn on the fixture, it will make a reset first. The display may show "XXEr" while there are
problems with one or more channels. "XX" stands for the channels equipped with a testing sensor.
For example, when the display shows "04Er", it means there is some error in channel 4. If there are
some errors on channel 4, channel 5, channel 6 at the same time, you may see the error message
"04Er", "05Er","06Er" flash repeatly for 5 times, and then the fixture will generate a reset signal, all
the stepper motors will reset. If the error messages maintain after performing reset more than 3
times, it will detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors
(including 3 errors), all the channels can not work properly; but if the fixture has less than 3 errors,
only the channels which have errors can not work properly, others can work as usual.
01Er:
Horizontal movement (PAN) error. This message will appear if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB)
after the reset. The PAN-position is not located in the default position after the reset.
02Er:
Horizontal movement (TILT) error. This message will appear if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB)
after the reset. The TILT-position is not located in the default position after the reset.
04Er:
Color-wheel 1 error. This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color-wheel 1 is not located in the default position after the reset.
05Er:
Color-wheel 2 error. This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color-wheel 2 is not located in the default position after the reset.
06Er:
Static gobo-wheel error. This message will appear after the reset of the ficture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The static gobo-wheel is not located in the default position after the reset.
07Er:
Rotating gobo-wheel error. This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunctions(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main PCB). The rotating gobo-wheel is not located in the default position after the reset.
08Er:
Rotating gobo indexing error. This message will appear after the reset of the fixture and if the magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver
circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
09Er:
Prism-wheel error. This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The prism-wheel is not located in the default position after the reset.
10Er:
Rotating prism index error. This message will appear after the reset of the fixture and if the magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver
circuit on the main PCB). The rotating prism index is not located in the default position after the reset.
11Er:
Zoom error. This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The zoom is not located in the default position after the reset.