Herunterladen Inhalt Inhalt Diese Seite drucken

Device Status; Diagnostics Led - Eaton EMS-...-SWD Serie Handbuch

Elektronischer motorstarter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3 Commissioning

3.2 Device status

3.2 Device status

3.2.1 Diagnostics LED

60
The individual SmartWire-DT modules indicate their communication status
with the aid of a diagnosis LED.
The diagnostics LED Ready can have the following states:
Table 9: Diagnostics LED "Ready" status messages
Status
Message
Off
No U
Aux
Orange continuous
No enable signal for the switching command
light
(missing enable signal at EN+ and EN- inputs)
Green continuous
The device has been added to the SmartWire-DT system
light
Green flashing (1Hz)
• Addressing process in progress
• After powering on the gateway
• After the configuration button on the gateway is pressed
• Module not in current configuration
• invalid part no.
A variety of diagnostic functions enable EMS-...-SWD electronic motor
starters to detect many peripheral internal and external faults. When a fault is
detected, the device will switch to a safe, switched-off state. Internal faults
cannot be reset, and will be stored in the device. Moreover, if more than
14 internal faults occur, it will no longer be possible to operate the device.
In the case of external faults, you will need to reset the corresponding fault in
order to leave the safe, switched-off state.
The following symbols are used throughout the table in order to represent
the LEDs:
View
Meaning
LED off
LED with a solid light
LED flashing
Electronic motor starter EMS-...-SWD 12/18 MN034002ZU-DE/EN www.eaton.com
voltage on the device

Werbung