Operating instructions

WARNING!
Before performing any work on the electric
power tool, pull out the mains plug.
Before switching on the power tool
Unpack the electric power tool and check
that no parts are missing or damaged.
Connection to the isolating
transformer – power tools
with contour plug
(LW 1202 N, LW 1503, LW 802 VR)
WARNING!
In accordance with VDE 0100 hand-
operated machines used for wet working
must be operated via a suitable isolating
transformer in accordance with EN 61558.
Damage to property!
Voltage specifications on the rating plate
of the electric power tool must correspond
with the output voltage of the isolating
transformer used.
The electric power tool features a contour
plug in accordance with IEC 60309-2 with
an earth contact in the 12 o'clock position
which allows the connection to an isolating
transformer with corresponding socket.
The FLEX isolating transformer TT 2000
complies with the stated regulations.
WARNING!
Have the contour plug on the wet grinder
replaced by appropriately qualified
technicians or customer service only.
Connection to the power supply –
power tools with PRCD switch
(LW 1202 SN/1503 S/802 VRS)
WARNING!
These machines may be operated with
the supplied PRCD switch only.
Before using the machine, always check
the PRCD switch.
18
LW 1202 N/~SN / LW 1503/~S / LW 802 VR/~S
Always check the machine before use:
1. Insert the mains plug into the socket.
2. Press "RESET" button.
The red indicator light must come on.
3. Press "TEST" button.
The PRCD switch must switch off and
the indicator light go out.
4. When the "RESET" button is pressed
again, it must be possible to switch
on the machine.
WARNING!
If the PRCD switch repeatedly switches off
when the machine is switched on or if the
PRCD switch does not trip, immediately
disconnect the machine from the power
supply.
Do not continue using the machine.
Have the PRCD switch replaced by appro-
priately qualified technicians or customer
service only.