Electrical connection

NOTE
All electrical connections must be carried out by
an authorised electrician.
Electrical installation and wiring must be carried
out in accordance with the stipulations in force.
F1145/F1245 must not be powered when in-
stalling SMS 40.
The wiring diagram is at the end of these installation in-
structions.
Connecting communication
Terminal block X1 on the SMS card (AA9) in SMS 40 is
connected to terminal block X4:9-12 on the input card
(AA3) in the heat pump.
Use cable type LiYY, EKKX or similar.
NOTE
If there is a RMU 40 in the installation it should
be connected to terminal X1 on the SMS card
(AA9).
SMS 40
F1145
F1245
SMS 40
F1145
7
8
GND
9
B
10
A
11
12V
12
13
7
8
9
10
11
12
13
F1245
SMS 40
GND
B
A
12V
GB
13