General
POOL 40 is an accessory that enables pool heating with
F1145/F1245/F1345.
A Shuttle valve (QN19) can be connected to control part,
or all, of the heating medium flow to a pool exchanger.
The reversing valve, or if so desired the reversing valves
(although using the same control signal), is/are installed
on the heating medium circuit which normally goes to a
radiator system. If the heat pump is a F1345 you determ-
ine in the control system how many compressors are
permitted to work with pool heating. External circulation
pump (GP10) to the climate system must be installed for
pool operation.
During pool heating the heating medium is circulated
between the heat pump and the pool exchanger using
the heat pump's internal circulation pumps. An external
circulation pump (GP9) circulates the heating medium
between the pool exchanger and the pool.
The external circulation pump (GP10) circulates the
heating medium water in the climate systems and the
additional heat can be engaged as necessary at the same
time as the external flow sensor continually meters the
heating demand of the house.
The heat pump controls the reversing valve (QN19), pool
circulation pump (GP9) and any heating circuit circulation
pumps (GP10) via POOL 40.
If the heat pump is an F1345 up to two different pool
systems can be connected and controlled individually, it
does require two POOL 40-accessories.
Contents
4 x
Cable ties
1 x
Actuator reversing valve
1 x
Shuttle valve
1 x
Kit for accessory card
2 x
Heating pipe paste
1 x
Aluminium tape
1 x
Insulation tape
2 x
Temperature sensor

Component positions

AA5-S2
AA5-X4
AA5
AA5-X2
AA5-F1

Electrical components

FA1
Miniature circuit-breaker. 10A
X1
Terminal block, power supply
AA5
Accessory card
AA5-X2
Terminal block, sensors and external
blocking
AA5-X4
Terminal block, communication
AA5-X9
Terminal block, circulation pumps and re-
versing valve
AA5-X10
Terminal block, reversing valve
AA5-S2
DIP switch
AA5-F1
Fine wire fuse, T4AH250V
Designations in component locations according to
standard IEC 81346-1 and 81346-2.
FA1
AA5-X9
X1
GB
11