Herunterladen Inhalt Inhalt Diese Seite drucken

Connection In Ducting Version; Connection In Recycling Version - Electrolux EFA9620 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16

Connection in Ducting Version

When installing the ducting version, connect
the hood to the chimney using either a flexible
or rigid pipe ø 150 or 120 mm, the choice of
which is left to the installer.
• To install a ø 120 mm air exhaust connec-
tion, insert the reducer flange 9 on the hood
body outlet.
• Fix the pipe using the pipe clamps 25 (not
provided).
• Remove charcoal filters, if present.

Connection in Recycling Version

• Fix the connection 15 to the frame using the
4 screws provided.
• Fix the flange 10 to the lower opening of the
connection 15.
• Connect the hood air outlet to the flange in
the lower part of the junction using a rigid or
flexible ø 150 tube (by installer's choice).
• Ensure that the charcoal filters have been fit-
ted.
Chimney assembly / Mounting the
hood body
• Position the upper chimney section and
fix the upper part to the frame using the 2
screws 12c (2,9 x 6,5) provided.
• Similarly, position the lower chimney section
and fix the lower part to the frame using the
2 screws 12c (2,9 x 6,5) provided.
Before fixing the hood body to the frame:
• Screw the 2 screws 12f half way into the
holes provided in the sides of the bottom of
the frame.
• Remove the grease filters from the hood
canopy.
• Remove any activated charcoal filters.
• Lift the hood canopy and engage the screws
12f in the slots (A) as far as they will go.
• Working from below, fix the hood canopy to
the frame (B), using the 4 screws 12q and
4 washers 22 provided, then tighten all the
screws securely.
electrolux 11