36 electrolux
Hood body installation
• Before attaching the hood body, tight-
en the two screws Vr located on the
hood body mounting points.
• Hook the hood body onto the screws
12a.
EN
• Fully tighten support screws 12a.
• Adjust screws Vr to level the hood
body

Connection in Ducting Version

When installing the ducted version, con-
nect the hood to the chimney using either
a flexible or rigid pipe ø 150 or 120mm,
the choice of which is left to the installer.
To install a ø 150
• To install the dumper 10.
• Fix the pipe in position using sufficient
pipe clamps (not supplied).
To install a ø 120
• To install a ø 125 mm air exhaust con-
nection, insert the reducer flange 9 on
the dumper 10.
• Fix the pipe in position using sufficient
pipe clamps (not supplied).
• Remove any activated charcoal filters.

Connection in Recycling Version

• Insert the connection extension pieces
laterally 14.1 in connec-tion 15.
• Insert the Connector 15 into the Sup-
port bracket 7.3 and fix it with a
screw.
• Make sure that the outlet of the exten-
sion pieces 14.1 is hori-zontally and
vertically aligned with the chimney out-
lets.
• Connect the air outlet connection 15
to the hood body outlet using either
a flexible or rigid pipe ø 150 mm, the
choice of which is left to the installer.
• Ensure that the activated charcoal fil-
ters have been inserted.