Connection of the circulation pump (GP13)
Connect the circulation pump (GP13) to AA5-X9:6 (230
V), AA5-X9:5 (N) and X1:3 (PE).
9
8
7
6
5
4
3
2
1
AA5-X9
Connection of the reversing valve motor
(QN12)
Connect the motor (QN12) to AA5-X9:2 (signal), AA5-
X9:1 (N) and AA5-X10:2 (230 V).
AA5-X9
AA5-X10
DIP switch
The DIP switch on the accessory card must be set as
follows.
18
AA25 External
GP13
1
2
3
X1
ACS 310
Externt
9
8
7
6
5
4
3
QN12
Svart
2
Blå
1
Brun
-X10
AA5-S2
Activating ACS 310
Program setting of ACS 310 can be performed via the
start guide or directly in the menu system.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or
need to change any of the settings, this can be done
in the menu system.
Menu 1.9.5 - Cooling settings
Menu 4.2 - "Operating mode"
Choose between different operating modes.
Menu 4.9.2 - Auto mode settings
Here you can set the temperatures, which control when
heating and cooling, respectively, are to be active in
AUTO operating mode
Menu 5.2 - system settings
Activating/deactivating of accessories.
Caution
Also see the Installer manual for VVM
310/VVM 320.