English, Installer manual - ACS 310
General
ACS 310 is an accessory that enables VVM 310 and
VVM 320 to control the production of cooling.
The cooling system supplies cooling from the heat
pump using a circulation pump via a reversing valve.
For the installation to work the cooling system must
flow freely, for example using a volume vessel for
cooling.
Operating mode cooling is activated by the temperat-
ure of the outdoor sensor and any room temperature
sensors, room units or separate room sensors for cool-
ing (if two different rooms are to be heated respectively
cooled at the same time for example.)
When cooling is required the cooling reversing valve
and the circulation pump are activated. Cooling pro-
duction regulates according to the cooling sensor and
a cooling set point value that is determined by the se-
lected cooling curve. Degree minutes are calculated in
response to the value on the external temperature
sensor for cooling out and the cooling set point value.
Contents
1 x
Circulation pump
2 x
Cable ties
1 x
Actuator reversing valve
1 x
Adapter kit, actuator
1 x
Shuttle valve
1 x
Unit box
1 x
Heating pipe paste
1 x
Aluminium tape
1 x
Insulation tape
1 x
Temperature sensor
1 x
Indoor sensor