interference

14.3 Error messages

The error message is displayed in short form as below:
Message displayed
AC failure
GSM Signal
Interference
Panel L.B.
Panel Tamper
(Sensor w/ Zone Name) + L.B.
(Sensor w/ Zone Name) + out
(Sensor w/ Zone Name) + Tamper
Sim Card?
Example: the message DC Z 01 L.B. means Zone 1 Door Contact is low battery.
Note
While you arm the system, if any of door contact or PIR is triggered, arming is also prohibited and the sensor
triggered will be displayed as error message.
Message displayed
(DC w/ Zone Name) + open
(IR w/ Zone Name) + Active
15.
Remote Commanding
The unit can be controlled by remote control commands sent via sms messages.
15.1 Remote commanding from a regular phone line
1. Dial the GSM phone number of your control panel and hang up on the first ring.
2. Dial the control panel again after 8 to 20seconds.
You will hear 2 beeps from the control panel via phone set.
3. Enter the user pin code (user 1 ~ user 4).
The first digit of pin code should be entered within 3 seconds.
A valid pin code should be entered with 20 sec. otherwise the Panel will hang up automatically.
4. If the pin code is correct, you will hear 2 beeps from the control panel via phone set.
5. Enter the 2-digit DTMF Control Command.
If the command is correct, you will hear 2 beeps; if not, you will hear 1 beep.
DTMF Remote Control Command Table
Control Command
00
01
10
11
20
21
30
V. 01 – 12/06/2013
CTC1000
the panel will light while this error message can be viewed on
LCD under Fault Display. No alarm event will be reported.
When the system is programmed with Interference detection ON
and when there is an interference detected for 30 seconds, the
yellow LED will light up. The error message can be viewed on
LCD under Fault Display in the user menu.
Meaning
AC Power Fail
GSM out of signal
interference detected
low battery on the control panel
sabotage on the control panel
low battery on the sensor
sensor out-of-order
sabotage on a sensor
SIM card missing
Meaning
Door Contact triggered
PIR triggered
Action
On Hook
Listen-in
Disarm
Arm
UR#1 deactivate
UR#1 activate
UR#2 deactivate
35