Event log

The alarm log memorises the last 20 system events including
all alarm events with device ID
all error warning events
all arming and disarming events
The logged events are displayed in reversed chorological order (most recent event first).
The log is marked with a Start label before the most recent entry and End after the oldest entry.
To view the event log:
While in alarm off mode:
1. Key in the user code and press OK to access User‟s Menu.
2. Press the  key repeatedly to select Log and then press OK.
The start of the log will be displayed.
3. Use & to scroll through all logged events.
13.
False Alarm Management
The device features the following false alarm management functions:
Twofold entry warning
When the system is armed and a device set to "entry" attribute is triggered, the system will begin an entry
countdown timer according to your entry time setting in General Setting. The purpose of the countdown timer is
to warn that alarm reports to the programmed telephone number are about to be made.
During the entry countdown timer, if another device not set to "entry" attribute is triggered, or a valid user pin
code is not entered before the timer expires, an alarm will be activated.
After the alarm is activated, the system will wait another 30 seconds before sending reports to programmed
telephone numbers.
If a valid user pin code is entered within 30 seconds, the alarm will be aborted and the system returns to
normal status.
If no valid user pin code is entered, the system will report burglar alarm to programmed telephone numbers.
Reporting of arming and disarming actions
If the Latch option is set to ON (factory default), all arming and disarming actions with user pin codes or
remote controllers will be reported.
Sequential verification reporting
If Verification is set to ON (factory default is OFF) and a burglar alarm is activated, if another different device
set to burglar attribute is triggered within 30 minutes, the system will send an alarm confirm report to the
programmed telephone numbers. Refer to section Verification on page 16 for details.
The sequential verification report will be sent in addition to the alarm report.
If the second device is triggered within the countdown delay, the sequential verification report will not be sent.
V. 01 – 12/06/2013
CTC1000
Fire Alarm
Fire Alarm
Emergency Alarm Emergency Alarm Emergency Alarm Emergency Alarm Emergency Alarm
Water Alarm
Water Alarm
Instant Burglar
Alarm
Warning Beep
(but no reporting)
Fire Alarm
Water Alarm
No response
32
Fire Alarm
Fire Alarm
Water Alarm
Water Alarm
No response
No response