Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman CTC1000 Bedienungsanleitung Seite 17

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 147
When the Mobility timer is set with a specified timer, the control panel will report to the Programmed phone
numbers when the timer runs out unless one of the following actions occurred in advance to reset the
timer:
In Home mode: whenever any Home Omit DC, IR is triggered, or whenever any of the keys of the
o
control panel is pressed;
In Disarm mode: whenever any of the DC or IR (except 24 Hr, Fire, Medical Emergency and Water) is
o
triggered, or whenever any of the keys of the control panel is pressed.
When the system is set to Away Arm, the timer automatically stops. When the system enters Home Arm or
Disarm mode, the timer automatically starts again.
Tamper Alarm
Allows setting when the siren will sound when the system is being tampered with.
Option
Function
Away Arm Only
The control panel will only raise a local alarm and send a report to the
monitoring centre when in Away mode.
If the alarm is in Home or Alarm off modes, the control panel will send
a report but the siren will not sound.
Normal
The control panel will raise a local alarm and send a report to the
monitoring centre in all modes.
Notes
Regardless of the siren setting, the panel will report the tamper alarm
by SMS to the first telephone number in all modes.
When tamper is restored, the panel also will report the tamper restore
event by SMS to the first telephone number.
Latch Option
The Latch Option logs the arming/disarming actions from all users done on the control panel and remote
control.
Notes
If the Latchkey Reporting feature is set to Off, the feature will be
hidden from the program menu (see section 7.5 Temp. Code).
If the Latchkey Reporting feature is set to On, all arming/disarming
actions of all users and the RCs will by default be reported to the
Central Monitoring Station.
For receiving the SMS-report, set the first telephone number as SMS
report.
Supervision
This option is used to enable system supervision function. When this option is set to ON, the control panel will
be able to receive check-in signals from its devices to indicate their proper functioning.
Options are: Disable, 8 Hours, 12Hours, and 24Hours.
Warning Beep
V. 01 – 12/06/2013
CTC1000
17
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis