Herunterladen Inhalt Inhalt Diese Seite drucken

Dc Current Measurement / A; Ac Current Measurement / A - TESTBOY TB 313 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TB 313:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
-
Max. input voltage range of 200 mV to 250 V
-
Max. input voltage: 600 V AC RMS, frequency range:
40-400 Hz

DC current measurement / A=

Use the selector switch to set the appropriate range. Connect the black
test lead into the "COM" socket, and the red test lead with the mA / 10A
socket (the appropriate socket opens automatically depending on the
measuring range). Using the test probes, touch the test points of the
test object. Read measurement value on the display. The current direc-
tion is indicated by the sign.
You must use the '10 A' socket when measuring currents
above 200 mA.
Direct current
Measurement
range
2 mA
20 mA
200 mA
10 A*
Overload protection: mA range is protected with a 200 mA self-resetting
fuse.
-
10A range is protected with F 10 A / 1000 V.
-
In the 10A range observe the maximum operating times!
*To protect against overheating, measurements should not
be taken for more than 10 seconds. Following this the de-
vice should be allowed to cool down for at least 15
minutes.

AC current measurement / A~

®
Testboy
TB 313
Resolution
Accuracy
1 μA
± 1.0 % of reading + 3 digits
0.01 mA
± 1.0 % of reading + 3 digits
0.1 mA
± 1.5 % of reading + 5 digits
0.01 A
± 2.0 % of reading + 10 digits
Operation
29