Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Troubleshooting; Maintenance And Cleaning - Klarstein 10030042 Anschluss- Und Anwendungshinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Plug the DC male port into the female port on the dehumidifier. Plug the AC adapter into the socket.
2. Press the ON/OFF button. When it is on, the indicator light is blue and the fan will keep running.
3. 3. If the water level is reach to the maximum level, the float will hit the switch and the indicator will turn
into red. In the meanwhile, the dehumidifier will not keep dehumidifying.
4. Wipe and dry the water tank and the dehumidifier.
Problem
After connecting, the red
indicator lights up
The dehumidifier does not
work
Before cleaning and maintenance please pull out the plug out of the socket outlet. Wipe the shell of the ap-
pliance with a soft damp cloth; never use abrasive agent and resolvent, as these will damage this appliance.

Operation

Troubleshooting

Possible Cause
The water tank is full
The float gets jammed
The power supply is cut off
DC switch is OFF
The air outlet is blocked

Maintenance and Cleaning

Solution
Empty the water tank and replace it
in correct position
Press the float and replace the water
tank
Check if the adaptor is plugged in
Turn the switch on
Maintain the minimum clearance at
least 10cm around the dehumidifier
when the unit is operating
8

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

10030043

Inhaltsverzeichnis