CENTER-4/RGBW
AC Power
Power Linking
Fuse Replacement
Mounting
Mounting Diagram
CENTER-4/RGBW has an auto-ranging power supply that can work
with an input voltage range of 100–240 VAC, 50/60 Hz.
Power linking is when products are daisy chained together through their Power In
and Power Out sockets, so that many products can be powered from one outlet.
1. Disconnect the product from power.
2. With a flat-head screwdriver, unscrew the fuse holder cap from
the housing.
3. Remove the blown fuse.
4. Replace with a fuse of the same type and rating.
5. Screw the fuse holder cap back in place and reconnect power.
Disconnect the product from power before replacing the fuse.
Before mounting this product, read the Safety Notes. Use one or two mounting
points and one safety cable per product. Make sure the mounting clamps are
capable of supporting the weight of the product.
Hanging/Mounting
Bracket
Safety
Cable
When using only one mounting clamp, be sure to use a clamp with a captive
bolt to prevent accidental loosening.
4
EN
Mounting Clamp
Rubber
Feet (x4)
for Floor
Mounting