3

Initial operation

3
Initial operation
WARNING!
Risk of explosion if other batteries are used
Use only Cleco lithium ion batteries, order no. 936400PT or order no. 935377. Never use other battery
types.
NOTE
LED
When charging is finished, the charger automatically shuts off the charging process. LED
nently in green.
4

Troubleshooting

Error
LED
ing power supply
LED
battery is plugged in
LED
even though battery is plugged
in
LED
LED
20
should not be flashing red before it is plugged in.
not lit despite function-
goes out when the
not lit up / not flashing
flashes red
flashes red
P2069BA/INT 2014-06
EN
EN
EN
Connecting the charger to the power network:
LED
is supplied.
Plug the battery into the charger and ensure
that it is securely connected.
LED
ging is in progress.
Cause
No power supply voltage.
Power cable defective.
Charger defective
Faulty charging electronics
No battery contact
Contacts are dirty.
Battery is damaged
Battery is damaged
The temperature in the battery is
too high or < 0°C (32 °F)
is lit up green and indicates that power
is flashing green, indicating that char-
is lit perma-
Measure
Check and restore the power
supply voltage.
Replace power cable.
Replace charger
Replace charger
Plug the battery in again
Clean the contacts of the
charger and battery
Check battery and replace if
necessary.
Check battery and replace if
necessary.
Remove battery from char-
ger and repeat charging after
approx. 10 min
69b_1_5 en.fm, 16.03.2015

Werbung

Inhaltsverzeichnis
loading