Herunterladen Inhalt Inhalt Diese Seite drucken

AFRISO Eurovac HV Betriebsanleitung Seite 82

Vorschau ausblenden Andere Handbücher für Eurovac HV:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5.4
Electrical connection
ELECTRIC SHOCK
Verify that the degree of protection against electric shock (protection class,
double insulation) is not reduced by the type of electrical installation.
Failure to follow these instructions will result in death or serious injury.
ELECTRIC SHOCK CAUSED BY LIVE PARTS
Disconnect the mains voltage supply before performing the work and ensure
that it cannot be switched on.
Verify that no hazards can be caused by electrically conductive objects or
media.
Failure to follow these instructions will result in death or serious injury.
UNAVAILABLE MONITORING FUNCTION
Verify that the product is connected by means of a permanently installed
cable connection.
Do not install mains plugs or switches in the supply line to the product.
Only power on/power off the product via the on-site mains fuse.
Failure to follow these instructions can result in equipment damage.
 Verify that the product is connected to mains by means of a permanently
installed cable without a switch.
1. If you want to route the mains cable or relay cable through the top of the
housing, replace the rubber grommet at the top of the housing by the
enclosed cable gland.
2. Route the mains cable through the upper or bottom cable gland into the
product.
3. Connect the phase to terminal L1 and the neutral conductor to terminal N.
Mounting
DANGER
DANGER
NOTICE
Eurovac HV
EN
24

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis