2.2
Intended use
The product is a leak detector for vacuum systems as per EN 13160-1,
class I (EN 13160-2).
This product may only be used to detect leaks in tanks which are not pres-
surised (i.e. operated under atmospheric conditions) and which are used for
the aboveground or underground storage of liquids.
Tanks
Double-walled steel tanks as per EN 12285-1/-2, DIN 6618-2/-4,
DIN 6619-2, DIN 6623-2, DIN 6624-2, DIN 6608, DIN 6616, DIN 6625
Steel or plastic tanks, double-walled or single-walled with leak protection
lining or leak protection coating, with suitable interstitial space as per
EN 13160-7.
The interstitial spaces of the tanks must be resistant to the liquid and its
vapours and must not contain leak detection fluid. Installation in the manhole
of underground tanks is only permitted with the approval of the authorities.
Liquids
Water-polluting liquids with a flash point >55 °C, which do not become vis-
cous and which do not release solid matter
AdBlue® (urea solution 32.5 %) as per DIN 70070
The product must be resistant to the liquid and its vapours. The materials
used are: PVC, silicone, ABS, NBR, PA6, EPP, EPDM. Resistance has been
proven for the liquids listed in the list of substances in chapter "List of sub-
stances".
Information on safety