OPERATING MANUAL
LOADING THE APPLIANCE / POSITIONING THE TRAYS
Fig. 7
Do not place the products to be cooled one on top of the other. The thickness must be less than 50 mm for quick
freezing and less than 80 mm for quick cooling (Figure 7).
Ensure that the space left between the trays is enough to allow air to circulate properly (Figure 8).
Place the trays close to the evaporator (Figure 9).
If the cabinet contains less than the maximum number of trays, space out the trays at an equal distance from one
another (Figure 10).

STORAGE TIMES

After chilling or cooling, a cooked product can be kept in a refrigerator for fi ve days after the quick cooling process
without any change of its organoleptic properties. Ensure that the temperature during storage is always between
0°C and 4°C, depending on the type of foodstuff. Storage time may be increased to approximately two weeks by
using vacuum processing.
After quick freezing, a cooked product can be kept safely for a period of 3 to 18 months, depending on the type of
foodstuff.
During this time, the temperature must be kept at -20°C or lower. Do not store cooked products at room tempera-
ture before they are quick cooled. Avoid any loss of moisture to ensure the foodstuff retains its freshness.
ALARMS
Error Code Fault
Er1
On standby, QuickCooling cannot be started.
During QuickCooling, the cycle stops and the card returns
to standby.
During storing, the cycle does not stop and the compres-
sor starts cyclically.
Er2
On standby, temperature-controlled QC cannot be started .
During temperature-controlled QC, it switches to time-
controlled cycle.
No effect during storing
E3
On standby, during QC and Storing, no effect.
Defrost, if any, stops through timeout.
Er4
Just signal on display
AL1
On standby and during defrost, no effect
AL2
On standby, no effect.
During QC and storing, the cycle stops and the card re-
turns to standby.
AL3
The running cycle stops, all outputs are de-activated, with
the exception of condenser fans
AL4
Needle not inserted
0.5 - 2 cm.
Fig. 8
Cause
Room Probe Faulty
Product Probe Faulty
Evaporator Probe Faulty
(only if evaporator probe
activated)
Condenser Probe Faulty
(only if condenser probe
activated)
Door Open Alarm
High Pressure Alarm
Condens. High Tempera-
ture Alarm (only if con-
denser probe activated)
Needle not
inserted
20
Fig. 9
Remedy
Check connections and operation
of the room probe
Check connections and operation
of the product probe
Check connection and operation
of the evaporator probe
Check connection and operation
of the condenser probe
Close the door
Eliminate the alarm cause, switch
off the card and then switch on
again.
Wait for condenser temperature
decrease
Check for proper insertion of the
needle
Fig. 10