To set the miter angle, loosen the knob on the miter
gauge.
Raise the small plate on the miter gauge for free setting.
Turn the miter gauge to the desired miter angle. Return
the small plate on the miter gauge to the original position
and tighten the knob clockwise securely.
Use of miter gauge
Fig.46
Slide the miter gauge into the thick grooves in the table.
Loosen the knob on the gauge and align to desired
angle (0° to 60°). Bring stock flush up against fence and
feed gently forward into the blade.
Auxiliary wood facing (miter gauge)
Fig.47
To prevent a long board from wobbling, fit the miter
gauge with an auxiliary fence board. Fasten with
bolts/nuts after drilling holes, but fasteners must not
protrude from the face board.
Carrying tool
Fig.48
Make sure that the tool is unplugged.
Carry the tool by holding the tool part shown in the
figure.
CAUTION:
Always secure all moving portions before carrying
the tool.
Always make sure that the blade guard is installed
in place before the carrying the tool.

MAINTENANCE

CAUTION:
Always be sure that the tool is switched off and
unplugged before attempting to perform inspection
or maintenance.
Never use gasoline, benzine, thinner, alcohol or
the like. Discoloration, deformation or cracks may
result.
Cleaning
Clean out sawdust and chips from time to time. Carefully
clean the blade guard and moving parts inside the table
saw.
Lubrication
To keep the table saw in tip-top running condition, and to
assure maximum service life, oil or grease the moving
parts and rotating parts from time to time.
Lubrication places:
Threaded shaft to elevate the blade
Hinge to rotate the frame
Elevation guide shafts on motor
Gear to elevate the blade
Guide rails for the rip fence
Shaft of the sub table (R) locking levers
Sliding part of the sub table (R)
Replacing carbon brushes
Fig.49
Remove and check the carbon brushes regularly.
Replace when they wear down to the limit mark. Keep
the carbon brushes clean and free to slip in the holders.
Both carbon brushes should be replaced at the same
time. Use only identical carbon brushes.
Use a screwdriver to remove the brush holder caps. To
replace the carbon brushes, remove the blade guard
and blade and then loosen the lock lever, tilt the saw
head and secure it at 45° bevel angle. Carefully lay the
tool on itself backward. Then loosen the brush holder
cap. Remove the worn carbon brushes, insert the new
ones and secure the brush holder caps.
Fig.50
To maintain product SAFETY and RELIABILITY, repairs,
any other maintenance or adjustment should be
performed by Makita Authorized Service Centers,
always using Makita replacement parts.
ACCESSORIES
CAUTION:
These
accessories
recommended for use with your Makita tool
specified in this manual. The use of any other
accessories or attachments might present a risk of
injury to
persons.
attachment for its stated purpose.
If you need any assistance for more details regarding
these accessories, ask your local Makita Service Center.
Table stand set (accessory)
Refer to the instruction manual for table saw stand that
is provided with the table saw stand as an optional
accessory.
Steel & Carbide-tipped saw blades
Sub table ( L)
Sub table ( back)
Rip fence
Miter gauge
Offset wrench 13-22
Wrench 19
Hex wrench 5
Joint ( for connecting to dust collector )
Auxiliary plate
Stand set
Sliding guide
13