Herunterladen Inhalt Inhalt Diese Seite drucken

Wear Parts - Oase AquaOxy 500 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für AquaOxy 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Removing the motor
A motor is located under the aerator housing. If the delivery rate of the aerator pump decreases, it is necessary to re-
place the two membranes. To do this, it is necessary to remove the motor.
Prerequisite: The housing is open. (
How to proceed:
G
1. Undo the screws of the cable strain relief and take out the power connection cable.
2. Remove the screws from the motor housing and lift off the housing top section.
– A gasket sheet is located between the top and bottom section of the housing. If it is displaced, it must be correctly
inserted during assembly.
3. Remove the screws on both sides of the motor housing.
4. Take the motor out of the housing.
– Use two bent paper clips or similar tool to lift the motor out of the housing.
Replace membranes
Prerequisite: The motor is removed. (
How to proceed:
H
1. Lift the air chamber from the membrane frame.
2. Undo and remove the screw in the support disc.
3. Remove the support disc.
4. Remove the membrane from the membrane frame.
5. Insert new membrane.
– Ensure that the membrane tab is positioned in the recess of the membrane frame and is correctly seated in the
groove.
6. Screw the support disc onto the membrane with the screw.
7. After replacing the two membranes: Install the motor. (
Installing the motor
How to proceed:
I
1. On both sides: Place the air chamber onto the membrane holder.
2. Place the motor back in its housing.
– Ensure that the outlet sockets are pointing upward.
3. Ensure that the O rings are correctly seated on the outlet sockets.
4. Fasten the motor on both sides with the screws at the housing top section.
– First turn in the higher screws.
– Tighten the screws crosswise.
5. Place the top section of the housing onto the bottom section and tighten the screws crosswise.
– Ensure that the strain relief of the power connection cable is correctly located in the recess of the housing.
– Ensure that the gasket sheet is inserted and correctly seated.
6. Place the cable strain relief of the power connection cable into the recess of the housing and secure.
7. Aerator housing: Place the housing top section in place and screw onto the housing bottom section.
– Ensure that the sealing ring is correctly seated.
Storage/Over-wintering
When the unit is in continuous operation it can remain in place at freezing temperatures.) Otherwise store the unit in-
doors in a dry room (room temperature).

Wear parts

Aerator stones, air filter and membranes are wear parts and are not covered by our warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Opening the housing)
Removing the motor)
Installing the motor)
- EN -
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis