Cleaning/replacing the impeller unit
How to proceed:
 C
1. Remove screws.
– The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Remove screws.
5. Remove the pump housing including its holding ring, sealing and impeller unit.
– Clean all components under running water using a soft brush, replace damage parts.
6. Reassemble the unit in the reverse order.
– Place the pump cable into the cable opening of the bottom strainer casing such that the cable will not be crushed
when closing the filter housing.
Storage/winter protection
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Thoroughly clean the unit and renew any damaged parts.
• Protect electrical connections from moisture and dirt.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.
Malfunction remedy
Malfunction
Pump does not start
Pump does not deliver
Insufficient delivered quantity
Pump switches off after a short running time

Wear parts

• Impeller unit
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
8
Cause
No mains voltage
Filter housing clogged
Filter housing clogged
Excessive loss in the supply hoses
Excessively soiled water
Water temperature too high
Remedy
Check mains voltage
Clean/check supply lines
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean strainer casings
Reduce hose length to the necessary mini-
mum, do not use unnecessary connection parts
Clean pump
Note maximum water temperature of +35 °C