Herunterladen Inhalt Inhalt Diese Seite drucken

Error Codes - Migatronic FOCUS MIG2 300 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für FOCUS MIG2 300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
One of the below mentioned error codes will be displayed if an error occurs during software update.
Error codes for control software 10001621.cry/10001641.cry
Error code
Cause and solution
There is no software present in the control unit.
Insert a SD card with software in the control unit
and turn on the machine.
SD card is not formatted.
The SD card must be formatted in a PC as FAT
and place the files down on the card or use another
SD card.
SD card contains no software.
See page 19.
SD card has more files of the same name.
See page 19.
The control unit has tried to read more data than is
accessible in the memory.
1. Insert the SD card again.
2. Replace the SD card.
3. Contact MIGATRONIC Service.
Software on the SD card is locked for another type
of control unit.
Use a SD card with software that matches your
control unit.
Software on the SD card is locked for another
control unit with another serial number/ bar code.
Use a SD card with software that matches your
control unit.
The internal copy protection does not allow access
to the microprocessor.
1. Insert the SD card in the machine again.
2. Contact MIGATRONIC Service.
The memory circuit is defective in the control unit.
Contact MIGATRONIC Service.
The memory circuit is defective in the control unit.
Contact MIGATRONIC Service.
The file has an error.
1. Insert the SD card in the machine again.
2. Exchange the SD card.
Gas error
Check the gas supply
Cancel the gas fault by briefly pressing any key
CAN communication error
Check intermediary cable/plug
The indicator is displayed in case of no circulation
of the cooling liquid due to faulty connection or
choking.
Check that the cooling hoses are correctly
connected, top up the water tank and check
welding hose and branches.
Cancel the cooling fault by briefly pressing any key.
Current sensor error
1. Check the current sensor
2. Contact MIGATRONIC service
Probe voltage
1. Check if welding wire is sticking in the weld pool
2. Contact MIGATRONIC service
Phase/voltage error
1. Check all three phases
2. Check for under-voltage
3. Contact MIGATRONIC service

ERROR CODES

Error codes for welding program package
10646201.bin
Error code
22
Cause and solution
There is no welding programs
present in the control unit
Insert a SD card with software in
the control unit and turn on the
machine. See page 19.
SD card is not formatted.
The SD card must be formatted in
a PC as FAT or use another SD
card.
It is only possible to have one file
with welding programs.
Make sure that there is only one
file with the number 106462xx.bin
on the SD card. See page 19.
The welding program package does
not match this control unit.
Use a SD card with software that
matches your control unit.
The welding program package is
locked for another control unit with
another serial number/ bar code.
Your software package is copy
protected and cannot be used for
a control unit without the correct
license.
The control unit is defective
Contact MIGATRONIC Service.
The file 106462xx.bin is not present
on the SD card.
See page 19.
The file 106462xx.bin has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
The Omega folder with files are not
present at the card or are saved
incorrectly.
1. Make a folder
MIGA_SW / OMEGA as described
on page 19 and save the files in
the folder.
2. Exchange the SD card

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Focus mig2 400

Inhaltsverzeichnis