Herunterladen Inhalt Inhalt Diese Seite drucken

Burner Description - Riello Burners Gulliver BLU BG5 Typ 388 T1 Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INDEX
1.

BURNER DESCRIPTION . . . . . . . . . . . . . 1

1.1 Burner equipment. . . . . . . . . . . . . . . . . . . 1
2.
TECHNICAL DATA . . . . . . . . . . . . . . . . . 2
2.1 Technical data . . . . . . . . . . . . . . . . . . . . . 2
2.2 Overall dimensions. . . . . . . . . . . . . . . . . . 2
2.3 Firing rate . . . . . . . . . . . . . . . . . . . . . . . . 2
3.
INSTALLATION . . . . . . . . . . . . . . . . . . . . 3
3.1 Boiler fixing . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Fuel supply . . . . . . . . . . . . . . . . . . . . . . . 3
3.3 Hydraulic systems . . . . . . . . . . . . . . . . . . 4
3.4 Electrical wiring . . . . . . . . . . . . . . . . . . . . 5
1.
BURNER DESCRIPTION
One stage light oil burner with low pollutant emissions (Nitric Oxide NOx, Carbon monoxide CO and unburnt
Hydrocarbons).
The burner has a device (compensator) which is integral with the air damper that sets the air output.
This device keeps the oxigen level as necessary for the combustion despite any changing of the room
temperature.
The dimension of the boiler's combustion chamber must respond to specific
values, in order to guarantee a combustion with the lowest polluting
emissions rate.
The RIELLO Technical Service Personnel will be glad to give
you all the imformation for a correct matching of this
burner to the boiler.
1 – Oil pump
2 – Control-box
3 – Reset button with
lock-out lamp
4 – Flange with insulating gasket
5 – Air damper adjustment
assembly
6 – Nozzle holder assembly
7 – Flame detector
8 – Hydraulic jack
9 – Temperature probe of the
compensator
10 – Start delaying device
CE Certification No.: 0036 0268/99 as 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
Burner with CE marking in conformity with EEC directives: EMC 89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
1.1
BURNER EQUIPMENT
Flange with insulating gasket . . . .No. 1
Screw and nuts for flange . . . . . .No. 1
2320
4.
WORKING . . . . . . . . . . . . . . . . . . . . . . .
4.1 Combustion adjustment. . . . . . . . . . . . . .
4.2 Pump pressure and air output . . . . . . . . .
4.3 Electrodes adjustment. . . . . . . . . . . . . . .
4.4 Flame detector adjustment . . . . . . . . . . .
4.5 Fuel heating . . . . . . . . . . . . . . . . . . . . . .
4.6 Burner start-up cycle . . . . . . . . . . . . . . . .
5.
MAINTENANCE . . . . . . . . . . . . . . . . . . .
7.
FAULTS / SOLUTIONS. . . . . . . . . . . . . . 10
Fig. 1
Screw and nuts for flange to be fixed to boiler . . . No. 4
Flexible oil pipes with nipples . . . . . . . . . . . . . . . . No. 2
1
GB
6
6
7
8
8
8
9
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis