How to proceed:
Open strainer casing and remove pump (B). Unscrew pump lid and remove impeller. Clean all components using clean
water and a brush.
After cleaning the pump, reassemble in the reverse order. Insert pump in the strainer casing. Regarding the 1500-2500
series of the filter pump, ensure correct seating of the rubber buffers used for the bearing of the pump. Route connec-
tion cable such that it cannot be pinched. Refit strainer lid and close.

Remedy of faults

Malfunction
The unit is not operating
Insufficient delivery rate
Unit switches off after a short running period
Disposal
N O T E
Do not dispose of this unit with domestic waste.
 Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
 Drain the unit as far as possible, clean thoroughly and check for damage.
 Empty all hoses, pipes and connections as far as possible.
 Thoroughly clean the unit, check it for damage and replace any damaged parts.
 Store the pump submerged and in a frost-free environment.
 Protect open plug connections from moisture and dirt.
Wear parts
 Impeller

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Repair
A damaged unit cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the regu-
lations.
10
Cause
No mains voltage
Impeller blocked
Strainer casing clogged
Excessive pressure losses in the hoses
Water temperature too high
www.oase-livingwater.com/spareparts
Remedy
Check mains voltage
Clean impeller
Clean strainer casing
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Note maximum water temperature of +35 °C