PROTECTION FUNCTIONS

Frost Protection Function
In cooling, if the temperature of the EVA pipe sensor is too low, the machine will
automatically enter protection status; if the temperature of the EVA pipe sensor rises to a
certain temperature, it can automatically revert to normal operation.
Overflow Protection Function
When water in the water pan exceeds the warning level, the machine will automatically
sound an alarm, and the W.F indicator will flash. At this point, you need to drainage
the water (details see Drainage Instructions at the end of this chapter). After the water is
emptied, the machine will get into standby status.
Automatic Defrosting
In heating, the machine has automatic defrosting function. After defrosting, the machine
will automatically return to the original status.
Overheat Protection
To protect the service life of the machine, the machine has overheat protection in heating
mode. During the protection period, the compressor and the lower motor will stop
operation and will automatically return to normal heating state after the temperature of
the machine recovers.
Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection
function after the compressor is turned off.