Timer Setting
• Press the Timer button to enter timed shutdown. Upon shutdown, press this button to enter timed
start. In the meanwhile, the timer indicator illuminates. Press the Timer button to enter timed
start/timed shutdown. Adjust the up or down button to set the timing time. The time will cycle in
the order of 1 to 24 to 1. The adjustment time of the timing function is relative time.
• After timed start is set, once the timed start time is reached, the unit will start. In the meanwhile,
the timer indicator will extinguish and the ambient temperature is displayed.
• After timed shutdown is set, once the timed shutdown time is reached, the unit will shut down. In
the meanwhile, the timer indicator will extinguish and the ambient temperature is displayed.
• ON/OFF operations caused by the button or remote control will clear all timing settings.
• Once the timing is determined, if the timer button is pressed once, it is possible to query the re-
maining timed start/shutdown time. If the timer button is pressed twice continuously within 5s, it
is possible to cancel timing.
Anti-freeze protection function
If the compressors operates continuously for more than 10 minutes and the pipe temperature is less
than 2°C continuously for 20 seconds, the compressor and water spraying motor turn off. LED dis-
plays E4 and the unit initiates the anti-frost protection function and the buttons are inactive (except
the OFF button). Once the pipe temperature exceeds 8°C, the protection is relieved, the original sta-
tus is restored and the unit meets the requirements for 3-minute delay protection of the compressor.
Full water protection function
When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the
full water indicator illuminates. In this case, you need to drain the condensate in the unit; otherwise,
the unit will shut down automatically after the buzzer gives off 5 beeps. The unit will be restored to
the previous operating status automatically once the water is fully drained.
Delay protection function of the compressor
This unit offers restart protection for the compressor. Except that the compressor may start immedi-
ately when the unit is energized for the first time, there is 3-minute delay start protection after the
compressor is shut down.

Water Tank and Continuous Drainage

Wassertank manuell entleeren
Once the unit shuts down upon full water, turn off the power of the unit and then unplug the power
plug. Move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit
• Put the vessel that holds water below the
water outlet at the back of the unit.
• Screw off the drain cap, unplug the water
plug and water will flow into the vessel that
holds water automatically. If the vessel that
holds water can not hold all water in the unit,
before the vessel that holds water is full of
water, block the water outlet with the water
plug as soon as possible to prevent the water
from flowing onto the ground or carpet.
IMPORTANT: Protect the drain cap and water plug properly. Tilt the unit slightly backward when
draining. Turn on the unit only after the water plug and drain cap are installed properly; otherwise,
the condensate of the unit will flow onto the ground or carpet.