Fault
Possible cause
Detergent fluid
Small parts and shavings
does not flow
sieve is blocked.
off
Filter mat is blocked.
Overflow holes in the
rinsing table are blocked.
Indicator lamp
Fill level sensor defec-
"Refill deter-
tive.
gent liquid" is
glowing despite
adeqaute fluid
level.
Too much oil in
Oil for disposal has spilt
the system
into the device.
Power supply switched
off during the night.
Microbes are destroyed.
Too little detergent liquid
in the tank.
This deactivates the
heating element.
Heating element is de-
fective.
Temperature of
Too little detergent liquid
the detergent
in the tank.
fluid is too low
This deactivates the
heating element.
Remedy
Clean sieve.
Replace filter mat.
Use multi-layered filter mat for
large quantities of dirt and pull
off one layer of fleece every
week.
Clean the overflow holes.
Get the defective fill level sen-
sor by Customer Service.
Scoop out the oil and dispose it
off.
Replace detergent liquid, if any,
and clean the device (see
"Maintenance and Care/ year-
ly"; however, use new deter-
gent solution).
Replace filter mat.
Pur one bottle of RM microbe
suspension into the device.
Refill detergent till the indicator
lamp "Refill detergent" goes off.
Check temperature of the de-
tergent fluid; get customer ser-
vice to replace defective
heating element, if any.
Refill detergent till the indicator
lamp "Refill detergent" goes off.
– 9
EN
of whom
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator