Herunterladen Inhalt Inhalt Diese Seite drucken

Sauna Heater Safety Clearances - Helo HIMALAYA D Produkthandbuch

Vorschau ausblenden Andere Handbücher für HIMALAYA D:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45
Installation and User Manual Himalaya D
2.8.

Sauna heater safety clearances

Effect
kW
6,8
9,0
10,5
Corner and wall installation: The sensor OLET 19 must be installed to ceiling in the side-line to the out side
Wall support
attaching the
heater to the wall or
benches
NOTE !
Mid-floor installation: If the heater is placed more than 60 mm from the wall the installation type is always a
mid-floor installation. The heater must be attached to the benches or to a similar structure using a wall support.
OLET 19
Figure 2 Safety clearances
Saunaroom
Volume
Height
min.
max.
min. mm
5
9
1900
8
13
1900
9
15
1900
Table 1 Safety clearances
from line. See the picture.
OLET 19
Sensor
870
A
330
D
1900
1030
F
870
A
A
helo
Minimum distance to
Side
In front
Ceiling
wall
of
A
D
mm
mm
mm
60
60
870
60
60
870
60
60
870
A
Wall support
H
attaching the heater to
the wall or benches
mm
H
1900
Wall support
attaching the heater to
the wall or benches
Stone
ca. kg
100
100
100
60
Water tank
Water tank
Sensor OLET 19 Installation area
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis