BTL7-S5 _ _ (B)-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S140/S147/KA _ _ /FA _ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
4.4.4

Connector type S147

BTL7 standard
Pin
BTL7-S5_ _-...-S147
BTL7-S5_ _B-...-S147
1
-Data
2
+Data
3
+Clk
4
-Clk
5
10 to 30 V
6
GND
7
Not used
1)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Tab. 4-5:
Connection assignment BTL7...-S147
Fig. 4-12: Pin assignment of S147 (view of connector pins of
transducer), 7-pin M16 circular plug
4.4.5

Cable connection

BTL7 standard
Cable
BTL7-S5_ _-...-KA
color
BTL7-S5_ _-...-FA
BTL7-S5_ _B-...-KA
BTL7-S5_ _B-...-FA
YE yellow
+Clk
GY gray
+Data
-Clk
PK pink
RD red
Not used
1)
-Data
GN green
BU blue
GND
BN brown 10 to 30 V
WH white
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Communication line
2)
Tab. 4-6:
Connection assignment BTL7... cable
12
english
BTL7 USB
configurable
BTL7-S510-...-KA
BTL7-S510-...-FA
BTL7-S510B-...-KA
BTL7-S510B-...-FA
+Clk
+Data
-Clk
La
2)
-Data
GND
10 to 30 V
Lb
2)
+Clk
–Clk
+Data
–Data
GND
BTL7...-
+24 V
cable
Fig. 4-13:
Connection example for BTL7-S...-cable 24 V DC with
evaluation/controller
Clk, Data and supply are twisted in pairs (see
Fig. 4-13).
4.5

Shielding and cable routing

Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect the transducer and controller using a shielded
cable.
Shielding: Copper filament braided, at least 85%
coverage
Connector version: Shield is interally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing.
Ground the cable shielding on the controller side
(connect with the protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer cylinder and strong, external
magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
For notes on cable length, see Technical data
on page 20, Fig. 8-2.
YE