Vitek VT-1765 Betriebsanweisung Seite 6

Ultraschallbefeuchter

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
ENGLISH
Note: You can determine amount of water in the water tank (3) with the help of the window (4).
5. Set the filled tank (3) on the body of the unit.
6. Insert the plug into the socket. Indication on/off (18) will light up on the display (9), the room tem-
perature indications (20), room relative humidity indication (22), will appear on the display and the
water tank lighting (7) will light up.
7. Switch on the unit by pressing the on/off button (11). The unit will switch on, and the on/off indica-
tion will go out (18), and indication (21) will light up showing steam intensity output mode "2".
8. After the end of operation switch off the unit by pressing the on/off button and unplug it.
Note: 30 seconds after the last pressing of any button the brightness of the display (9) will
decrease automatically.
Functions of the buttons on the control panel (10)
"IONIZATION"/ "ИОНИЗАЦИЯ" on/off button (14)
Negatively charged ions (anions), contained in the air, are useful for health. Anions improve operation
of the lungs, stimulate blood circulation and protect a person from respiratory diseases. In closed
rooms, especially when the equipment operates there is a lack of anions in the air that is why addi-
tional ionization of the air is required.
− To switch on ionization mode of the air touch the "IONIZATION" on/off button (14) the indication
(25) will appear on the display (9). Touch the "IONIZATION" button (14) again and the ionization
mode will switch off and the indication (25) will disappear from the display (12).
Outgoing steam intensity setting button «MAX/MIN» /"МАКС. /МИН"
− By pressing the "MAX/MIN" button (15) you can select intensity of steam output mode:
"1"
- low intensity;
"2"
- medium intensity,
"3"
- high intensity.
− Indications (21) show the selected intensity of steam output mode
Humidity level indoors setting button (16)
"HUMIDITY"/ "ВЛАЖНОСТЬ"
− Pressing the "HUMIDITY" button (16) you can set the desired level of the room humidity from 45 to
90% with step of 5%. Digital value (22) of the desired humidity and indication (23) will be displayed
(9) during the setting. When the humidity in the room reaches the preset value, steam supply will
stop. We recommend maintaining relative humidity 40-60% in the room.
Note:
• After setting of the relative humidity in 5 seconds the humidity value in the room (22) will
appear on the display (9), the indication (23) will be flashing.
• To view the value of the humidity, touch the "HUMIDITY" button (16), digital value of the
humidity will be displayed for 5 seconds, after it, value of the relative humidity in the room
will be displayed.
"TIMER"/ "ТАЙМЕР" time setting button (17)
− By repeated pressing of the "TIMER" button (17) you can set operation time of the air humidifier
from 1 to12 hours with step of 1 hour. Digital value of the timer time (19) will be displayed (9).
Note: Time (in hours) remaining before the unit switch off will be shown on display (9). Sym-
bols "00" mean that there is less than one hour left before the unit switch off.
VT-1765.indd 6
VT-1765.indd 6
6
29.09.2011 12:33:20
29.09.2011 12:33:20